Virtual Cell Virtual Cell WebsiteSchool of Health Sciences WebsitePurdue University Website
About the Virtual CellDownload VCExamplesTheoryUser ManualHelpExecute VC Simulation
Set fractional step size (FSDX=)
SIMCON: keyword (or sample input files)


Syntax:    SIMCON: FSDX={fractional step size}
Example: SIMCON: FSDX=0.01


Purpose: Fractional time step taken during the exposure.
Data Type:
real number
Unit:
n/a
Default: 1 (output results at start of simulation and just after the radiation delivery ends).
Comments:  Use a value FSDX= 0.01, for example, to observe cell- and damage-repair kinetics during the radiation exposure.  Set FSDX=1 to speed up calculations (no cell or damage repair kinetic information will be output during the radiation exposure). See also the TSAX parameter.


School of Health Sciences
Purdue University
Disclaimer

Last updated: 10 June, 2011