Virtual Cell Virtual Cell Website School of Health Sciences Website Purdue University Website
About the Virtual Cell Download VC Examples Theory User Manual Help Archive of Biological Datasets
Calibrated Input File (RMR)
Human Bladder Carcinoma Cells

/*
  RMR Model Input File for Human Bladder Carcinoma Cells (RT112)
  REFERENCE:
      Wilkins RC, Ng CE, Raaphorst GP. Comparison of High Dose Rate, Low Dose Rate, and High Dose Rate
      Fractionated for Optimizing Differences In Vitro. Radiation Oncology Investigations. 6: 209-215 (1998)
  PREPARED BY: JULIEN PARTOUCHE (julien@tamu.edu)
 DATE: 21-JUL-2003
*/
MODEL: DRM=RMR CKM=QECK !Model Specification
CELL: DNA=5.667D+09 NC=46
IRAD: CL=90 !Radiation damage to DNA
CLRP: RHT=2.2829899E-03 BMR=4.8929477E-01 PHI=1.2367501E-02 A0=0.00
CCKM: TCC=10 TPOT=20 GF=0.0 N0=1 KAP=1.0D+38 VOL=1
RBM: KX=6.0E+06 FMAX=1 !Analysis of PFGE data

! Parameters that impact on solution accuracy
SOLVER: DBLV=0 ETOL=1.0E-09 MXSS=999999 HMAX=10

! Parameters that control the time steps and stopping criteria
SIMCON: FSDX=1 TSAX=12 TCUT=96 FRDL=1.0E+00 RCUT=1.0D-09

!IRRADIATION CONDITIONS (single fraction)
RADX: ADR=RX1 AD=RX2
RX1 = 0.528 67.2 / !dose rate (Gy/h)
RX2 = 0 0.1 0.25 0.5 1 1.5 2 3 4 5 6 7 8 9 10 12.5 15 17.5 20 25 30 35 /

School of Health Sciences
Purdue University
Disclaimer

Last updated: 10 June, 2011
Webmaster