Virtual Cell Virtual Cell Website School of Health Sciences Website Purdue University Website
About the Virtual Cell Download VC Examples Theory User Manual Help Archive of Biological Datasets
Calibrated Input File (TLK)
PC-3 Prostate Carcinoma Cells

/*
 REFERENCE:
  Deweese TL, Shipman JM, Dillehay LE, and Neslon WG. Sensitivity of human prostatic carcinoma lines to low dose rate radiation exposure.   The Journal of Urology. 159, 591-598 (1998)
 PREPARED BY: JULIEN PARTOUCHE (julien@tamu.edu)
DATE: 22-JUL-2003
REVISED: RD STEWART 11-NOV-2003
Increased DSB yield to 40 DSB/cell-Gy and refit

 COMMENT:
*/
MODEL: DRM=TLK CKM=QECK
CELL: DNA=5.667D+09 NC=46
IRAD: CL=DSB
CLRP: RHT=HT4R BMR=1.5520561E-04 PHI=PML A0=PMR
CCKM: TCC=10 TPOT=20 GF=0.0 N0=1 KAP=1.0D+38 VOL=1
RBM: KX=6.0E+06 FMAX=1 !Analysis of PFGE data 

! TLK model inputs (simple and complex double strand breaks)
DSB = 30 10 / !Radiation damage to DNA
HT4R = 0.25 9.8389317E+00 / !Half-times for DSB repair
PML = 3.2075369E-03 / !Probability a misrejoined DSB is lethal
PMR = 0 0 / !Probability DSB is rejoined correctly


! Parameters that impact on solution accuracy
SOLVER: DBLV=0 ETOL=1.0E-09 MXSS=999999 HMAX=10

! Parameters that control the time steps and stopping criteria
SIMCON: FSDX=1 TSAX=12 TCUT=96 FRDL=1.0D+00 RCUT=1.0D-09

!IRRADIATION CONDITIONS (single fraction)
RADX: ADR=RX1 AD=RX2
RX1 = 0.25 60 / !dose rate (Gy/h)
RX2 = 0 0.1 0.25 0.5 1 1.5 2 3 4 5 6 7 8 9 10 12.5 15 17.5 20 25 30 35 /