REFERENCE:
Kelland LR, Tonkin KS, Steel GG. A comparison of the in vivo radiation
responses of three human
cervix carcinomas. Radiotherapy and Oncology. 16 (1989) 55-63
PREPARED BY: JULIEN PARTOUCHE (julien@tamu.edu)
DATE: 22-JUL-2003
*/
MODEL: DRM=LPL CKM=QECK !Model
Specification
CELL: DNA=5.667D+09 NC=46
IRAD: CL=25 FL=1.9195436E-01
CLRP: RHT=1.1867212E+00 BMR=3.0324048E-04 GAM=0.25 A0=0.95
CCKM: TCC=10 TPOT=20 GF=0.0 N0=1 KAP=1.0D+38 VOL=1
RBM: KX=6.0E+06 FMAX=1 !Analysis of PFGE data
! Parameters that impact on solution accuracy
SOLVER: DBLV=0 ETOL=1.0E-09 MXSS=999999 HMAX=10
! Parameters that control the time steps and stopping criteria
SIMCON: FSDX=1 TSAX=12 TCUT=96 FRDL=1.0D+00 RCUT=1.0D-09
!IRRADIATION CONDITIONS (single fraction)
RADX: ADR=RX1 AD=RX2
RX1 = 1.92 60 / !dose rate (Gy/h)
RX2 = 0 0.1 0.25 0.5 1 1.5 2 3 4 5 6 7 8 9 10 12.5 15 17.5 20 25 30 35
|